Every topic and message the adapter publishes or accepts, and the CLI flags. Addressing follows the Unified Namespace (UNS): ecv1/{device}/{component}/{instance}/{class}[/channel]. For the data/control plane model, see explanation.md; for client recipes, the how-to guides.

  • {device} — the resolved Thing name (the last hierarchy level).
  • {component} — the component UNS token, modbus-adapter.
  • {instance} — a device instance id (plc1, …) for data/evt, and optionally on cmd topics to address a device by topic; absent on the component-scope cmd inbox, the state keepalive, and metric (whose envelope identity carries main).

All messages use the EdgeCommons JSON envelope: {header, identity, tags, body}. The library stamps the top-level identity ({hier, path, component, instance}) on every message built from config. tags is arbitrary business metadata. Request/reply carries header.reply_to + header.correlation_id; the reply is published to reply_to with the same correlation_id.

"identity": {
"hier": [ { "level": "site", "value": "lab" }, { "level": "shop", "value": "s1" },
{ "level": "line", "value": "l1" }, { "level": "device", "value": "gw-01" } ],
"path": "lab/s1/l1/gw-01", "component": "modbus-adapter", "instance": "plc1"
}
Class Message Direction Topic Scope Reply
data SouthboundSignalUpdate adapter → bus ecv1/{device}/modbus-adapter/{instance}/data/{signal}
evt evt adapter → bus ecv1/{device}/modbus-adapter/{instance}/evt/{severity}/{connection|write}
cmd sb/read bus → adapter ecv1/{device}/modbus-adapter[/{instance}]/cmd/sb/read instance {ok,result}
cmd sb/write bus → adapter ecv1/{device}/modbus-adapter[/{instance}]/cmd/sb/write instance {ok,result}
cmd sb/status bus → adapter ecv1/{device}/modbus-adapter[/{instance}]/cmd/sb/status instance {ok,result}
cmd sb/signals bus → adapter ecv1/{device}/modbus-adapter[/{instance}]/cmd/sb/signals instance {ok,result}
cmd sb/browse bus → adapter ecv1/{device}/modbus-adapter[/{instance}]/cmd/sb/browse instance {ok,result}
cmd sb/pause bus → adapter ecv1/{device}/modbus-adapter[/{instance}]/cmd/sb/pause instance {ok,result}
cmd sb/resume bus → adapter ecv1/{device}/modbus-adapter[/{instance}]/cmd/sb/resume instance {ok,result}
cmd reconnect bus → adapter ecv1/{device}/modbus-adapter[/{instance}]/cmd/reconnect instance {ok,result}
cmd repoll bus → adapter ecv1/{device}/modbus-adapter[/{instance}]/cmd/repoll instance {ok,result}
metric southbound_health, ModbusConnection, ModbusInventory, ModbusPoll, ModbusPublish, ModbusCommand adapter → bus (auto) ecv1/{device}/modbus-adapter/metric/{metricName}
state keepalive adapter → bus (auto) ecv1/{device}/modbus-adapter/state

The Scope column is each verb’s declared command scope, the value a describe reply carries in commands[].scope. Every verb this adapter serves is instance-scoped: it acts on one configured slave.

Fleet consumers subscribe the six UNS wildcards — telemetry is one filter, ecv1/+/+/+/data/#; events ecv1/+/+/+/evt/#; metrics ecv1/+/+/+/metric/#; state ecv1/+/+/+/state. state/metric/cfg/log are library-owned reserved classes — a component publish to them is rejected; the adapter only ever mints data/evt topics via the data()/events() facades and cmd replies via the command inbox — never a hand-assembled topic string.

The read/write/control surface is served through the library’s command inbox, which subscribes both command scopes on the primary connection: the component scope ecv1/{device}/modbus-adapter/cmd/# and the instance scope ecv1/{device}/modbus-adapter/+/cmd/#. A request’s verb is the topic channel after the /cmd/ marker and must equal header.name. Built-in verbs (ping, status, describe, reload-config, get-configuration) ship with every component; the adapter adds the sb/* + reconnect/repoll verbs below.

Every request is addressed to one configured device. Each verb declares the instance scope, and the addressing resolves in this order:

  • An instance-scoped request (ecv1/{device}/modbus-adapter/{instance}/cmd/…) addresses the device named by the topic’s instance token; no body selector is needed.
  • A component-scoped request (ecv1/{device}/modbus-adapter/cmd/…) addresses the device named by the instance field in the request body.
  • A body instance that disagrees with the topic’s instance token is refused with BAD_ARGS, before the adapter runs the verb.
  • A request that names no instance at all addresses the sole configured device; on a multi-device adapter it is BAD_ARGS.
  • An addressed instance that names no configured device is NO_SUCH_INSTANCE.

The reply body is {"ok": true, "result": <verb result>} on success, or {"ok": false, "error": {"code", "message"}} on failure.

The adapter uses the standardized southbound error-code set:

Code Meaning
BAD_ARGS Malformed request — no addressed instance on a multi-device adapter, a body instance conflicting with the topic’s instance token, a bad sb/browse cursor or ref, or a browse request mixing the paged and hierarchical forms.
PAUSED The whole operation is prohibited while the instance is paused — repoll on a paused instance.
NO_SUCH_INSTANCE The instance selector names no configured device.
WRITE_NOT_ALLOWED Every entry of an sb/write batch is refused by the instance’s writes.allow list.
WRITE_FAILED Every attempted (allow-listed) write in the batch was rejected by the device.
RECONNECT_FAILED A reconnect attempt could not re-establish the link.

The sb/read reply’s reads[] entries (below) always carry all five fields explicitly:

Field Type Notes
value number | boolean | string Per the signal’s type (see data-types.md).
quality string Normalized GOOD | BAD | UNCERTAIN.
qualityRaw string Good, or the Modbus exception / timeout text on failure.
sourceTs null Modbus has no device timestamp.
serverTs string Adapter read time, ISO-8601 UTC.

data-class samples (below) go through the data() facade instead, which omits a field rather than emitting it null, and defaults an omitted quality to GOOD with qualityRaw: "unspecified" (Modbus has no native quality codes) rather than the literal string "Good".

Per the southbound four-slot timestamp model, serverTs is the capture time: the adapter stamps it the moment the register read completes (on the poll path and in sb/read replies alike), so a batched publish carries the read-time stamp; sourceTs is absent (Modbus supplies no device time), and receivedTs is not emitted (a direct-client adapter’s receipt and capture coincide).

SouthboundSignalUpdate (adapter → bus, data class)

Section titled “SouthboundSignalUpdate (adapter → bus, data class)”

Published through the library’s data() facade (gg.instance(id).data()), which constructs the body, sanitizes the channel, mints the topic, and stamps the envelope identity — the adapter only ever calls .signal(id).name(n).address(a).device(...).add_samples(...).signal_path(p).publish(). Topic ecv1/{device}/modbus-adapter/{instance}/data/{signal}{signal} is the sanitized signal name. The stable signal.id and protocol-native signal.address stay in the body (consumers key on those, not the topic channel). Quality has no Modbus-native meaning, so a successful read omits it and the facade defaults it to GOOD with qualityRaw: "unspecified" (a synthesized-vs-device-reported marker); a failed read passes an explicit BAD with the exception text as qualityRaw.

"body": {
"device": { "adapter": "modbus", "instance": "plc1", "endpoint": "tcp://10.0.0.50:502 unit=1" },
"signal": {
"id": "u1/holding/0/float32",
"name": "Temperature",
"address": { "unitId": 1, "table": "holding", "address": 0, "type": "float32", "wordOrder": "big", "byteOrder": "big" }
},
"samples": [ { "value": 21.4, "quality": "GOOD", "qualityRaw": "unspecified", "serverTs": "2026-07-03T01:48:00Z" } ]
}

Published when a polled value changes (publishMode: onChange, gated by the signal’s deadband) or every poll (always). One message carries one signal’s samples (one, or many when publish.batchMs > 0).

Each entry is gated by the instance’s writes.allow[] allow-list — matched on the stable signal.id, before any device I/O (a signal not on the list is refused without touching the device). An empty writes.allow makes the instance read-only. Body:

"body": { "instance": "plc1", "writes": [ { "name": "Setpoint", "value": 42.5 } ] }
// result: { "id": "plc1", "written": 1, "results": [ { "signal": "Setpoint", "value": 42.5, "ok": true } ] }

A single {name,value} object (no writes array) is also accepted. A signal-ref is either { "name": "<configured signal>" } (friendly; uses that signal’s table/type/order) or explicit { "unitId"?, "table", "address", "type", "wordOrder"?, "byteOrder"?, "scale"?, "offset"?, "count"? }. Entries not on writes.allow, without value, an unresolvable ref, a read-only table (discrete/input), or a bit signal are reported per-entry as {"ok": false, "error": …}. When every entry is an allow-list refusal the reply is a WRITE_NOT_ALLOWED error; when every attempted write is rejected by the device it is a WRITE_FAILED error. Each attempted write also emits an evt/info/write/evt/warning/write audit event. Writes use FC5/FC15 (coil), FC6/FC16 (holding).

// request body
"body": { "instance": "plc1", "signals": [ { "name": "Temperature" }, { "unitId": 1, "table": "input", "address": 0, "type": "uint16" } ] }
// reply body: { "ok": true, "result": { "id": "plc1", "reads": [
// { "signal": { "id": "...", "address": {...} }, "value": 21.4, "quality": "GOOD", "qualityRaw": "Good", "sourceTs": null, "serverTs": "..." } ] } }

Unresolvable refs are omitted (match by signal). A signal that errors returns an entry with quality: BAD and the exception in qualityRaw.

  • sb/statusresult = { "id", "state", "connected", "paused", "metrics": { "read": {interval,total}, "write": {interval,total} } }. state is the instance state token (ONLINE / PAUSED / BACKOFF / CONNECTING, see State keepalive) — the same token the keepalive publishes for that instance, so the pulled answer and the pushed one always agree.
  • sb/signalsresult = { "id", "signals": [ { "name", "unitId", "signalId", "address" }, ... ] } — the whole configured/polled inventory in one shot.
  • sb/browse — a walk of the configured inventory (Modbus has no address-space discovery), in two mutually exclusive request forms:
    • Paged (body {instance?, cursor?, max?}) → result = { "id", "entries": [ { "id", "name", "type" }, ... ], "cursor"? }. cursor is an opaque offset token, present only while more pages remain. Distinct from sb/signals (single-shot, full).
    • Hierarchical — the treeBrowser panel mode, selected by the presence of ref (body {instance?, ref, depth?, maxRefs?}) → result = { "id", "mode": "hierarchical", "root": { "nodeId", "name", "nodeClass", "dataType", "refs": [ { "referenceType": "contains", "target": {...} } ] }, "refCount", "depth", "truncated" }. ref: "root" is the device node whose contains refs are the signal inventory (bounded by maxRefs); a signal id is a known leaf ("refs": []); an unknown ref is BAD_ARGS. depth and maxRefs are clamped to 1..4 and 1..1000. Mixing ref/depth/maxRefs with cursor/max, or sending depth/maxRefs without ref, is BAD_ARGS.
  • sb/pause (body {instance}) → suspends polling/publishing for the instance; confirmed + idempotent; result = { "id", "paused": true, "changed" }.
  • sb/resume (body {instance}) → resumes a paused instance; confirmed + idempotent; result = { "id", "paused": false, "changed" }.
  • reconnect (body {instance}) → drops and re-establishes the Modbus link (one bounded attempt); result = { "id", "connected" } or a RECONNECT_FAILED error.
  • repoll (body {instance}) → forces one immediate poll cycle; result = { "id", "polled": <groups> }. Refused with PAUSED while the instance is paused.

Published through the library’s events() facade (gg.instance(id).events()): severity derives the channel evt/{severity}/{type}, so the topic and the body can never disagree — identical in shape to the OPC UA reference adapter.

"body": {
"severity": "critical", "type": "connection", "message": "Modbus link down",
"timestamp": "2026-07-03T01:48:00Z", "context": { "endpoint": "tcp://10.0.0.50:502 unit=1" },
"alarm": true, "active": true
}
  • evt/critical/connection — a Modbus link up/down transition per instance, modeled as a stateful alarm: raise_alarm("connection", ...) on drop (alarm:true, active:true), clear_alarm("connection", ...) on restore (active:false) — both ride the same evt/critical/connection channel, so a console tracking evt/critical/# sees both ends. Context carries {endpoint} (the connection description, e.g. slave address).
  • evt/info/write / evt/warning/write — a per-write audit record, info on success and warning on failure — emit("write", message, {signal, value, error?}, severity).

A fleet consumer subscribing ecv1/+/+/+/evt/critical/# sees only alarm-grade events without per-adapter knowledge of the channel shape.

Metrics (metric class, reserved — automatic)

Section titled “Metrics (metric class, reserved — automatic)”

The metric subsystem publishes health and Modbus operational metrics on the reserved metric class (ecv1/{device}/modbus-adapter/metric/{metricName}) through MetricEmitter; the component never addresses that topic itself. For every metric’s dimensions, measures, units, and diagnostic purpose, see Reference - Metrics.

State keepalive (state class, reserved — automatic)

Section titled “State keepalive (state class, reserved — automatic)”

The library’s heartbeat publishes the state keepalive on the reserved state class (ecv1/{device}/modbus-adapter/state) every ~5 s — the component never addresses that topic itself. The RUNNING keepalive also carries an instances array: one entry per configured slave (component.instances[]), so a fleet consumer sees every slave’s up/down state under the one component without a separate UNS instance per slave (identity, data, and lifecycle stay under main).

"body": {
"status": "RUNNING",
"uptimeSecs": 3600,
"instances": [
{ "instance": "plc1", "connected": true, "state": "ONLINE", "detail": "tcp://10.0.0.50:502 unit=1" },
{ "instance": "plc2", "connected": true, "state": "PAUSED", "detail": "tcp://10.0.0.51:502 unit=1" },
{ "instance": "plc3", "connected": false, "state": "CONNECTING" }
]
}
  • connectedlive liveness, driven by the poll reads themselves: any response that arrives (data, or even a slave exception for e.g. an illegal address) marks the link up; a transport/IO error, a ModbusIOException, or no response marks it down. It is not pymodbus’s cached client.connected (which reflects intent and lags a socket that died mid-session), so a mid-session southbound loss shows up promptly as connected: false on the next keepalive.
  • state — the instance’s condition in the shared vocabulary, the same token sb/status returns: ONLINE (the slave answers reads), PAUSED (sb/pause is latched and the link is up, so the instance is deliberately quiet rather than stale), BACKOFF (the link is down and being retried), CONNECTING (the instance’s device has not come up yet). Link truth wins: a paused instance whose link is down reports BACKOFFCONNECTING before its first connect — never PAUSED, and the pause stays visible in sb/status’s paused field.
  • detail — the connection describe string (tcp://host:port unit=N / rtu://COM@baud unit=N); omitted before that slave’s device has connected (connected is then false).
  • instances is present only on the RUNNING keepalive (the best-effort STOPPED shutdown state, and a keepalive with no configured slaves, omit it).
Flag Values Notes
--platform GREENGRASS | HOST | KUBERNETES | auto Default auto.
--transport MQTT [path] | IPC HOST/K8s use MQTT; the path is the messaging config.
-c/--config FILE <path> | ENV | GG_CONFIG | CONFIGMAP | … Default from the platform.
-t/--thing <name> IoT Thing name; the {device} token of every UNS topic.